- Main
- Production
- Input/output
- ENMV-1 with four interfaces
Array
(
[ID] => 487
[~ID] => 487
[TIMESTAMP_X] => 10/29/2025 05:07:42 pm
[~TIMESTAMP_X] => 10/29/2025 05:07:42 pm
[MODIFIED_BY] => 12
[~MODIFIED_BY] => 12
[DATE_CREATE] => 11/05/2014 02:52:31 pm
[~DATE_CREATE] => 11/05/2014 02:52:31 pm
[CREATED_BY] => 6
[~CREATED_BY] => 6
[IBLOCK_ID] => 18
[~IBLOCK_ID] => 18
[IBLOCK_SECTION_ID] => 2341
[~IBLOCK_SECTION_ID] => 2341
[ACTIVE] => Y
[~ACTIVE] => Y
[GLOBAL_ACTIVE] => Y
[~GLOBAL_ACTIVE] => Y
[SORT] => 10
[~SORT] => 10
[NAME] => ENMV-1 with four interfaces
[~NAME] => ENMV-1 with four interfaces
[PICTURE] =>
[~PICTURE] =>
[LEFT_MARGIN] => 184
[~LEFT_MARGIN] => 184
[RIGHT_MARGIN] => 233
[~RIGHT_MARGIN] => 233
[DEPTH_LEVEL] => 2
[~DEPTH_LEVEL] => 2
[DESCRIPTION] =>
[~DESCRIPTION] =>
[DESCRIPTION_TYPE] => text
[~DESCRIPTION_TYPE] => text
[SEARCHABLE_CONTENT] => ENMV-1 WITH FOUR INTERFACES
[~SEARCHABLE_CONTENT] => ENMV-1 WITH FOUR INTERFACES
[CODE] =>
[~CODE] =>
[XML_ID] =>
[~XML_ID] =>
[TMP_ID] => 388b32cc78f8db46910b6298e986676c
[~TMP_ID] => 388b32cc78f8db46910b6298e986676c
[DETAIL_PICTURE] =>
[~DETAIL_PICTURE] =>
[SOCNET_GROUP_ID] =>
[~SOCNET_GROUP_ID] =>
[LIST_PAGE_URL] => /en/products/index.php?ID=18
[~LIST_PAGE_URL] => /en/products/index.php?ID=18
[SECTION_PAGE_URL] => /en/products/list.php?SECTION_ID=487
[~SECTION_PAGE_URL] => /en/products/list.php?SECTION_ID=487
[IBLOCK_TYPE_ID] => products
[~IBLOCK_TYPE_ID] => products
[IBLOCK_CODE] => productset_en
[~IBLOCK_CODE] => productset_en
[IBLOCK_EXTERNAL_ID] => 00000
[~IBLOCK_EXTERNAL_ID] => 00000
[EXTERNAL_ID] =>
[~EXTERNAL_ID] =>
)
Array
(
[514] => Array
(
[ID] => 514
[NAME] => ENMV-1-24/0
[PICTURE] => 205234
[DESCRIPTION] =>
– 24 discrete inputs for wet contact or dry contact signals (using the built-in 24VDC power supply)
[IBLOCK_ID] => 18
[DEPTH_LEVEL] => 3
[IBLOCK_SECTION_ID] => 487
)
[695] => Array
(
[ID] => 695
[NAME] => ENMV-1-16/3R
[PICTURE] => 205240
[DESCRIPTION] =>
– 16 discrete inputs for wet contact or dry contact signals (using the built-in 24VDC power supply)
– 3 digital outputs (250 VAC/8 A, 250 VDC/0.12 A).
[IBLOCK_ID] => 18
[DEPTH_LEVEL] => 3
[IBLOCK_SECTION_ID] => 487
)
[696] => Array
(
[ID] => 696
[NAME] => ENMV-1-16/6
[PICTURE] => 205247
[DESCRIPTION] =>
– 16 discrete inputs for wet contact or dry contact signals (using the built-in 24VDC power supply)
– 6 digital outputs (300 VDC/0.12 A, 250 VAC/0.12 A).
[IBLOCK_ID] => 18
[DEPTH_LEVEL] => 3
[IBLOCK_SECTION_ID] => 487
)
[627] => Array
(
[ID] => 627
[NAME] => ENMV-1-0/20
[PICTURE] => 205253
[DESCRIPTION] =>
– 20 digital outputs 300 VDC/0.12 A, 250 VAC/0.12 A
[IBLOCK_ID] => 18
[DEPTH_LEVEL] => 3
[IBLOCK_SECTION_ID] => 487
)
[513] => Array
(
[ID] => 513
[NAME] => ENMV-1-0/22
[PICTURE] => 205259
[DESCRIPTION] =>
– 20 digital outputs 300 VDC/0.12 A, 250 VAC/0.12 A
– 2 digatal outputs 250 VDC/3.4 A
[IBLOCK_ID] => 18
[DEPTH_LEVEL] => 3
[IBLOCK_SECTION_ID] => 487
)
[998] => Array
(
[ID] => 998
[NAME] => ENMV-1-8P2T/0
[PICTURE] => 205265
[DESCRIPTION] =>
– 8 programmable analog DC inputs: 0... 20 mA; − 20...0...20 mA; 0...5 mA; − 5...0...5 mA;
– 2 inputs for thermocouples Type K and thermistors Pt100, 100P, Pt500, 500P, Pt1000, 1000P.
[IBLOCK_ID] => 18
[DEPTH_LEVEL] => 3
[IBLOCK_SECTION_ID] => 487
)
[930] => Array
(
[ID] => 930
[NAME] => ENMV-1-8X8/0
[PICTURE] => 205271
[DESCRIPTION] =>
– 8 analog DC inputs (-250... 250 V, -10... 10 V, -200... 200 mV, -75... 75 mV, -20... 20 mA, -5... 5 mA);
– 8 discrete inputs for wet contact or dry contact signals (using the built-in 24VDC power supply)
[IBLOCK_ID] => 18
[DEPTH_LEVEL] => 3
[IBLOCK_SECTION_ID] => 487
)
[2391] => Array
(
[ID] => 2391
[NAME] => ENMV-4X8/4P
[PICTURE] => 205277
[DESCRIPTION] =>
– 4 analog inputs: ±250 V, ±10 V, ±200 mV, ±75 mV, ±20 mA, ±5 mA
– 8 discrete inputs for wet contact or dry contact signals (using the built-in 24 VDC power supply)
– 4 analog outputs: 4...20 mA, 0…5(20,24) mA, ±5(20,24) mA
[IBLOCK_ID] => 18
[DEPTH_LEVEL] => 3
[IBLOCK_SECTION_ID] => 487
)
)
Array
(
[ID] => 1214
[~ID] => 1214
[IBLOCK_ID] => 19
[~IBLOCK_ID] => 19
[IBLOCK_CODE] => support_en
[~IBLOCK_CODE] => support_en
[NAME] => ES Configurator
[~NAME] => ES Configurator
[DETAIL_TEXT] =>
Software tool for configuring ENIP-2, ESM, ENMV, PDC, ENMU, PMU. English interface available. Manual.
[~DETAIL_TEXT] =>
Software tool for configuring ENIP-2, ESM, ENMV, PDC, ENMU, PMU. English interface available. Manual.
[PROPERTY_SAVE_VALUE] =>
[~PROPERTY_SAVE_VALUE] =>
[PROPERTY_SAVE_VALUE_ID] =>
[~PROPERTY_SAVE_VALUE_ID] =>
[PROPERTY_VERSION_VALUE] => 1.0.1.14
[~PROPERTY_VERSION_VALUE] => 1.0.1.14
[PROPERTY_VERSION_VALUE_ID] => 507388
[~PROPERTY_VERSION_VALUE_ID] => 507388
[PROPERTY_CREATION_DATE_VALUE] => 07/10/2026 12:00:00 am
[~PROPERTY_CREATION_DATE_VALUE] => 07/10/2026 12:00:00 am
[PROPERTY_CREATION_DATE_VALUE_ID] => 507389
[~PROPERTY_CREATION_DATE_VALUE_ID] => 507389
[PROPERTY_LINK_VALUE] => /software/esconfigurator.zip
[~PROPERTY_LINK_VALUE] => /software/esconfigurator.zip
[PROPERTY_LINK_VALUE_ID] => 507390
[~PROPERTY_LINK_VALUE_ID] => 507390
[IBLOCK_SECTION_ID] => 394
[~IBLOCK_SECTION_ID] => 394
[PROPERTY_CHECKSUM_VALUE] => 93f48dd375e40cf945173e519ca2ace6
[~PROPERTY_CHECKSUM_VALUE] => 93f48dd375e40cf945173e519ca2ace6
[PROPERTY_CHECKSUM_VALUE_ID] => 507391
[~PROPERTY_CHECKSUM_VALUE_ID] => 507391
[SORT] => 100
[~SORT] => 100
[DETAIL_TEXT_TYPE] => html
[~DETAIL_TEXT_TYPE] => html
)
Array
(
[ID] => 1248
[~ID] => 1248
[IBLOCK_ID] => 19
[~IBLOCK_ID] => 19
[IBLOCK_CODE] => support_en
[~IBLOCK_CODE] => support_en
[NAME] => BootLoader (Firmware Updater)
[~NAME] => BootLoader (Firmware Updater)
[DETAIL_TEXT] =>
[~DETAIL_TEXT] =>
[PROPERTY_SAVE_VALUE] =>
[~PROPERTY_SAVE_VALUE] =>
[PROPERTY_SAVE_VALUE_ID] =>
[~PROPERTY_SAVE_VALUE_ID] =>
[PROPERTY_VERSION_VALUE] => 2.0.1.3
[~PROPERTY_VERSION_VALUE] => 2.0.1.3
[PROPERTY_VERSION_VALUE_ID] => 180040
[~PROPERTY_VERSION_VALUE_ID] => 180040
[PROPERTY_CREATION_DATE_VALUE] => 03/06/2025 10:28:11 am
[~PROPERTY_CREATION_DATE_VALUE] => 03/06/2025 10:28:11 am
[PROPERTY_CREATION_DATE_VALUE_ID] => 180041
[~PROPERTY_CREATION_DATE_VALUE_ID] => 180041
[PROPERTY_LINK_VALUE] => /software/bootloader.zip
[~PROPERTY_LINK_VALUE] => /software/bootloader.zip
[PROPERTY_LINK_VALUE_ID] => 180042
[~PROPERTY_LINK_VALUE_ID] => 180042
[IBLOCK_SECTION_ID] => 393
[~IBLOCK_SECTION_ID] => 393
[PROPERTY_CHECKSUM_VALUE] =>
[~PROPERTY_CHECKSUM_VALUE] =>
[PROPERTY_CHECKSUM_VALUE_ID] =>
[~PROPERTY_CHECKSUM_VALUE_ID] =>
[SORT] => 1000
[~SORT] => 1000
[DETAIL_TEXT_TYPE] => html
[~DETAIL_TEXT_TYPE] => html
)
ENMV-1 with four interfaces
A series of I/O modules with two to four interfaces. The interfaces are independently configurable and support up to six connections. The interface configuration is determined at the time of order.
— 2 x RS-485, 1 or 2 x 100Base-TX
— IEC 61850-8-1, IEC 60870-5-101/104, Modbus RTU/TCP support
— Discrete input and output, analog input and output, temperature measurement
— Programmable logic
– 24 discrete inputs for wet contact or dry contact signals (using the built-in 24VDC power supply)
Hover over to see the location
- Power input
- 2 x RS-485
- 2 x Ethernet 100Base-TX
- USB port
-
8 digital inputs
- 16 digital inputs
- Indication of signal states for digital inputs/outputs
- Indication of power, interface, and diagnostics
Hover over to see the location
- Power input
- 2 x RS-485
- Ethernet 100Base-TX
- USB port
-
8 digital inputs
- 16 digital inputs
- Indication of signal states for digital inputs/outputs
- Indication of power, interface, and diagnostics
Hover over to see the location
- Power input
- 2 x RS-485
- USB port
-
8 digital inputs
- 16 digital inputs
- Indication of signal states for digital inputs/outputs
- Indication of power, interface, and diagnostics
- Input of discrete signals
- Discrete output Input of analog signals
- Independent operation or addition of the functionality of measuring devices ENIP-2, ESM
- Registration of changes in the states of discrete timestamped signals in non-volatile memory
- Storing 1000 recent discrete signal changes and a 40-record event log
- Data transmission via RS-485 and Ethernet
|
Interfaces Exchange protocols |
2 × RS‑485: Modbus RTU, IEC 60870-5-101 |
|
Event logging |
1000 events data log |
|
Time sync |
according IEC 60870‑5‑101, |
|
Power supply voltage |
18...36 VDC, 40...160 VDC, 120...370 VDC, 100...265 VAC (45...55 Hz) |
|
Power consumption |
12 VA |
|
Operating temperature |
−40...+70 °С |
|
Housing |
75 × 100 × 110 mm (IP40) |
|
Mounting |
DIN-rail mounting |
Software
Software tool for configuring ENIP-2, ESM, ENMV, PDC, ENMU, PMU. English interface available. Manual.