Array
(
[ID] => 761
[~ID] => 761
[TIMESTAMP_X] => 09/03/2026 01:47:30 pm
[~TIMESTAMP_X] => 09/03/2026 01:47:30 pm
[MODIFIED_BY] => 14
[~MODIFIED_BY] => 14
[DATE_CREATE] => 07/18/2019 09:57:08 pm
[~DATE_CREATE] => 07/18/2019 09:57:08 pm
[CREATED_BY] => 4
[~CREATED_BY] => 4
[IBLOCK_ID] => 18
[~IBLOCK_ID] => 18
[IBLOCK_SECTION_ID] => 2345
[~IBLOCK_SECTION_ID] => 2345
[ACTIVE] => Y
[~ACTIVE] => Y
[GLOBAL_ACTIVE] => Y
[~GLOBAL_ACTIVE] => Y
[SORT] => 10
[~SORT] => 10
[NAME] => IEC 61850 support
[~NAME] => IEC 61850 support
[PICTURE] =>
[~PICTURE] =>
[LEFT_MARGIN] => 454
[~LEFT_MARGIN] => 454
[RIGHT_MARGIN] => 467
[~RIGHT_MARGIN] => 467
[DEPTH_LEVEL] => 2
[~DEPTH_LEVEL] => 2
[DESCRIPTION] =>
[~DESCRIPTION] =>
[DESCRIPTION_TYPE] => text
[~DESCRIPTION_TYPE] => text
[SEARCHABLE_CONTENT] => IEC 61850 SUPPORT
[~SEARCHABLE_CONTENT] => IEC 61850 SUPPORT
[CODE] => iec-61850-support
[~CODE] => iec-61850-support
[XML_ID] => 761
[~XML_ID] => 761
[TMP_ID] =>
[~TMP_ID] =>
[DETAIL_PICTURE] =>
[~DETAIL_PICTURE] =>
[SOCNET_GROUP_ID] =>
[~SOCNET_GROUP_ID] =>
[LIST_PAGE_URL] => /en/products/index.php?ID=18
[~LIST_PAGE_URL] => /en/products/index.php?ID=18
[SECTION_PAGE_URL] => /en/products/list.php?SECTION_ID=761
[~SECTION_PAGE_URL] => /en/products/list.php?SECTION_ID=761
[IBLOCK_TYPE_ID] => products
[~IBLOCK_TYPE_ID] => products
[IBLOCK_CODE] => productset_en
[~IBLOCK_CODE] => productset_en
[IBLOCK_EXTERNAL_ID] => 00000
[~IBLOCK_EXTERNAL_ID] => 00000
[EXTERNAL_ID] => 761
[~EXTERNAL_ID] => 761
)
Array
(
[672] => Array
(
[ID] => 672
[NAME] => ES61850.enip2
[PICTURE] => 175647
[DESCRIPTION] =>
IEC 61850-8-1 support for ENIP-2 (modifications A3E4, A2E4X2, A2E4X2FS, A2E4X2FM). Up to 4 clients MMS, publicate 8 GOOSE, subscribe 32 GOOSE.
Protocol implementation is tested with a positive result for compliance with IEC 61850 ed. 1 and ed. 2.
The following units are tested (number of topical and tests/total number of tests):
|
1
2
2+
5
6
9a
|
Basic Exchange (22/24)
Data Sets (6/6)
Data Set Definition (24/24)
Unbuffered Reporting (9/19)
Buffered Reporting (7/21)
GOOSE Publish (13/13)
|
9b
12a
12d
|
GOOSE Subscribe (23/30)
Direct Control (5/12)
Enhanced SBO Control (9/19)
|
[IBLOCK_ID] => 18
[DEPTH_LEVEL] => 3
[IBLOCK_SECTION_ID] => 761
)
[671] => Array
(
[ID] => 671
[NAME] => ES61850.enmv
[PICTURE] => 175655
[DESCRIPTION] =>
IEC 61850-8-1 support for ENMV-1 I/O module (modifications A1E4, A2E4, A2E4X2, A1E4X2FM, A1E4X2FS).
Up to 4 clients MMS, up to 8 MMS reports, publicate 8 GOOSE, subscribe 64 GOOSE.
[IBLOCK_ID] => 18
[DEPTH_LEVEL] => 3
[IBLOCK_SECTION_ID] => 761
)
[802] => Array
(
[ID] => 802
[NAME] => ES61850.esm
[PICTURE] => 175667
[DESCRIPTION] => Additional 8 GB memory for ESM
[IBLOCK_ID] => 18
[DEPTH_LEVEL] => 3
[IBLOCK_SECTION_ID] => 761
)
[803] => Array
(
[ID] => 803
[NAME] => ES61850.encm3
[PICTURE] => 175658
[DESCRIPTION] => IEC 61850-8-1 support for ENCM-3 (MMS server and GOOSE publisher, MMS and GOOSE subscriber).
[IBLOCK_ID] => 18
[DEPTH_LEVEL] => 3
[IBLOCK_SECTION_ID] => 761
)
[804] => Array
(
[ID] => 804
[NAME] => ES61850.encs3
[PICTURE] => 175661
[DESCRIPTION] => IEC 61850-8-1 support for ENCS-3m (MMS server and GOOSE publisher, MMS and GOOSE subscriber).
[IBLOCK_ID] => 18
[DEPTH_LEVEL] => 3
[IBLOCK_SECTION_ID] => 761
)
[805] => Array
(
[ID] => 805
[NAME] => PTPv2.encs2
[PICTURE] => 175664
[DESCRIPTION] => IEEE 1588v2 PTP support for ENCS-2
|
Parameter
|
Possible values
|
|
Type
|
Layer 2 (Ethernet)
|
|
Domain
|
0…127
|
|
Delay mechanism
|
Peer-to-peer, end-to-end
|
|
Operation mode
|
One step, two step
|
|
Sync interval
|
0.125, 0.25, 0.5, 1, 2, 4, 8, 16 сек
|
|
Announce interval
|
0.125, 0.25, 0.5, 1, 2, 4, 8, 16 сек
|
|
VLAN ID
|
0…4095
|
[IBLOCK_ID] => 18
[DEPTH_LEVEL] => 3
[IBLOCK_SECTION_ID] => 761
)
)
Protocols
Support for the IEC 61850-8-1 protocol for ENIP-2 multifunction measuring transducers, ESM multifunction measuring devices, ENMV-1 input/output modules, ENCM-3 and ENCS-3m data acquisition devices. Also support for PTPv2 protocol for ENCS-2 time correction units.
IEC 61850-8-1 support for ENIP-2 (modifications A3E4, A2E4X2, A2E4X2FS, A2E4X2FM). Up to 4 clients MMS, publicate 8 GOOSE, subscribe 32 GOOSE.
Protocol implementation is tested with a positive result for compliance with IEC 61850 ed. 1 and ed. 2.
The following units are tested (number of topical and tests/total number of tests):
|
1
2
2+
5
6
9a
|
Basic Exchange (22/24)
Data Sets (6/6)
Data Set Definition (24/24)
Unbuffered Reporting (9/19)
Buffered Reporting (7/21)
GOOSE Publish (13/13)
|
9b
12a
12d
|
GOOSE Subscribe (23/30)
Direct Control (5/12)
Enhanced SBO Control (9/19)
|