- Main
- Production
- Оptions and Accessories
- Surge protection
Array
(
[ID] => 766
[~ID] => 766
[TIMESTAMP_X] => 09/03/2026 01:47:30 pm
[~TIMESTAMP_X] => 09/03/2026 01:47:30 pm
[MODIFIED_BY] => 14
[~MODIFIED_BY] => 14
[DATE_CREATE] => 07/18/2019 10:33:44 pm
[~DATE_CREATE] => 07/18/2019 10:33:44 pm
[CREATED_BY] => 4
[~CREATED_BY] => 4
[IBLOCK_ID] => 18
[~IBLOCK_ID] => 18
[IBLOCK_SECTION_ID] => 2345
[~IBLOCK_SECTION_ID] => 2345
[ACTIVE] => Y
[~ACTIVE] => Y
[GLOBAL_ACTIVE] => Y
[~GLOBAL_ACTIVE] => Y
[SORT] => 20
[~SORT] => 20
[NAME] => Surge protection for RS-485 lines
[~NAME] => Surge protection for RS-485 lines
[PICTURE] => 175759
[~PICTURE] => 175759
[LEFT_MARGIN] => 468
[~LEFT_MARGIN] => 468
[RIGHT_MARGIN] => 483
[~RIGHT_MARGIN] => 483
[DEPTH_LEVEL] => 2
[~DEPTH_LEVEL] => 2
[DESCRIPTION] =>
[~DESCRIPTION] =>
[DESCRIPTION_TYPE] => text
[~DESCRIPTION_TYPE] => text
[SEARCHABLE_CONTENT] => SURGE PROTECTION FOR RS-485 LINES
[~SEARCHABLE_CONTENT] => SURGE PROTECTION FOR RS-485 LINES
[CODE] => surge-protection-for-rs-485-lines
[~CODE] => surge-protection-for-rs-485-lines
[XML_ID] => 766
[~XML_ID] => 766
[TMP_ID] =>
[~TMP_ID] =>
[DETAIL_PICTURE] => 175760
[~DETAIL_PICTURE] => 175760
[SOCNET_GROUP_ID] =>
[~SOCNET_GROUP_ID] =>
[LIST_PAGE_URL] => /en/products/index.php?ID=18
[~LIST_PAGE_URL] => /en/products/index.php?ID=18
[SECTION_PAGE_URL] => /en/products/list.php?SECTION_ID=766
[~SECTION_PAGE_URL] => /en/products/list.php?SECTION_ID=766
[IBLOCK_TYPE_ID] => products
[~IBLOCK_TYPE_ID] => products
[IBLOCK_CODE] => productset_en
[~IBLOCK_CODE] => productset_en
[IBLOCK_EXTERNAL_ID] => 00000
[~IBLOCK_EXTERNAL_ID] => 00000
[EXTERNAL_ID] => 766
[~EXTERNAL_ID] => 766
)
Array
(
[767] => Array
(
[ID] => 767
[NAME] => ESP485-1
[PICTURE] => 175757
[DESCRIPTION] => Surge protection for one RS-485 line, mounting on DIN-rail
[IBLOCK_ID] => 18
[DEPTH_LEVEL] => 3
[IBLOCK_SECTION_ID] => 766
)
[768] => Array
(
[ID] => 768
[NAME] => ESP485-2
[PICTURE] => 175792
[DESCRIPTION] => Surge protection for two RS-485 lines, mounting on DIN-rail
[IBLOCK_ID] => 18
[DEPTH_LEVEL] => 3
[IBLOCK_SECTION_ID] => 766
)
[769] => Array
(
[ID] => 769
[NAME] => ESP485-SG
[PICTURE] => 175794
[DESCRIPTION] => Surge protection for one RS-485 line with protection of signal ground, mounting on DIN-rail
[IBLOCK_ID] => 18
[DEPTH_LEVEL] => 3
[IBLOCK_SECTION_ID] => 766
)
[1020] => Array
(
[ID] => 1020
[NAME] => ESP485-SG2
[PICTURE] => 209673
[DESCRIPTION] => Surge protection for one RS-485 line with protection of signal ground, mounting on DIN-rail
[IBLOCK_ID] => 18
[DEPTH_LEVEL] => 3
[IBLOCK_SECTION_ID] => 766
)
[770] => Array
(
[ID] => 770
[NAME] => ESP-LAN
[PICTURE] => 209676
[DESCRIPTION] => Surge protection for Ethernet 10/100/1000 BASE-TX, mounting on DIN-rail
[IBLOCK_ID] => 18
[DEPTH_LEVEL] => 3
[IBLOCK_SECTION_ID] => 766
)
[891] => Array
(
[ID] => 891
[NAME] => EMP-GN-SMA
[PICTURE] => 209680
[DESCRIPTION] => Surge protection for GPS/GLONASS-antenna feeder, SMA-f/f (suitable for GPS-P antennas GPS-P.10 and GPS-P.20). Mounting on DIN-rail. Included is a 0.5 meter SMA-SMA adapter cable.
[IBLOCK_ID] => 18
[DEPTH_LEVEL] => 3
[IBLOCK_SECTION_ID] => 766
)
[1021] => Array
(
[ID] => 1021
[NAME] => EMP-GN-TNC
[PICTURE] => 209682
[DESCRIPTION] => Surge protection for GPS/GLONASS-antenna feeder, TNC-F/f (suitable for GPS-P antennas50 and GPS-ET.50). Mounting on DIN-rail. Included is a 0.5 meter TNC-SMA adapter cable.
[IBLOCK_ID] => 18
[DEPTH_LEVEL] => 3
[IBLOCK_SECTION_ID] => 766
)
)
Surge protection
ESP series – protection devices for RS-485, Ethernet 10/100/1000 Base-TX or GLONASS/GPS antenna feeder interfaces.
| ESP485-1 | ESP485-2 | ESP485-SG | ESP485-SG2 | |
|
Number of protected communication lines |
1 | 2 | 1 | 1 |
| Protection of the signal ground | no | no | yes | yes |
|
Connection technology, cross-section of connected conductors |
Screw terminals, 2.5 mm2 |
Screw terminals, 2.5 mm2 |
Screw terminals, 2.5 mm2 |
Connectors RJ45 or push-in terminals (0.75 mm2), screw terminals PE (2.5 mm2) |
|
Operating (maximum) voltage, V |
6 (7) | 6 (7) | 6 (7) | 6 (7) |
| Rated current, mA | 100 | 100 | 100 | 100 |
| Rated (maximum) discharge current, kA | 1 (10) | 1 (10) | 1 (10) | 1 (2) |
| Response time, µs | < 10 | < 10 | < 10 | < 10 |
| Dimensions, mm |
91 × 65 × 18 |
91 × 65 × 18 |
91 × 65 × 18 | 117 × 44 × 22 |
| Operating temperature, °C | -40...+70 | -40...+70 | -40...+70 | -40...+70 |
Protection devices of interfaces Ethernet 10/100/1000 Base-TX
| Maximum voltage | 60 В |
| Load |
Rated current – 1 A Maximum current – 1,5 A |
| Pulse discharge current (8/20 µs) |
1 kA (line-ground) 2 kA (ground-ground) |
| Accordance IEEE 802.3 | af, at, bt |
| Construction |
114 × 42.8 × 22.5 mm, IP20 |
| Interface connector | RJ45 shielded |
| Connector of grounding protective | 2-pole screw terminal block, 0.2...2.5 mm2 (24...12 AWG), 0.4 N·m |
| Operating temperature | -40 to +70 °C |
| Installation | DIN-rail TH35 |
GLONASS/GPS antenna feeder protection devices
|
|
EMP-GN (TNC) |
EMP-GN (SMA) |
|
Connectors on the device |
TNC f/f |
SMA f/f |
|
Applicability to GLONASS/GPS antennas |
GPS-P.50МP GPS-B3.50МP GPS-ET.50МP |
GPS-P.10МP GPS-P.20МP GPS-B3.10МP GPS-B3.20МP |
|
Gap gap voltage |
90 V ± 30 % |
|
|
Maximum pulse discharge current (8/20 µs) |
2 kA |
|
|
Rated current |
4 A |
|
|
Frequency range |
0...2,6 GHz |
|
|
Introduced attenuation |
< 1,5 dB |
|
|
Wave resistance |
50 Om |
|
|
Response time (pulse over 100 V/µs) |
< 5 µs |
|
|
Overall dimensions |
82 × 42 × 22,5 mm (SMA) 80 × 45,5 × 22,5 mm (TNC) |
|
|
Weight |
50 g |
|
|
Operating temperature |
-40…+70 °C |
|